Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
2.
Catheter Cardiovasc Interv ; 95(4): 783-790, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31062927

RESUMO

OBJECTIVES: To compare the incidence of permanent pacemaker implantation (PPI) with the CoreValve and Evolut R prostheses, to evaluate the implantation depth with both types of prostheses, and to study factors predicting the need for PPI. BACKGROUND: The Evolut R CoreValve can be recaptured and repositioned during deployment, allowing a more precise implantation. METHODS: A total of 208 patients treated with CoreValve and 137 patients treated with Evolut R were analyzed. The depth of the prosthesis in the LVOT was measured by angiography in the annular perpendicular view projection after deploymen in all patients. RESULTS: Baseline conduction abnormalities were comparable between the groups (85/208, 40.9% vs. 53/137, 38.7%; p = 0.69). The mean prosthesis depth was 10.3 ± 8.6 mm in the CoreValve group and 5.5 ± 2.7 mm in the Evolut R group; p < 0.0001. Conduction disturbances after valve implantation were more frequent with the CoreValve (new-onset left bundle branch block: 93, 44.7% vs. 16, 11.7%; p < 0.05, first-degree atrioventricular block: 23, 11.1% vs. 5, 3.6%; p < 0.05). In addition, the incidence of PPI was significantly lower with Evolut R (45, 21.6% vs. 15, 10.9%; p = 0.01). The predictors of the need for PPI were the mean depth of the prosthesis (OR: 1.13, 95% CI: 1.06-1.21; p < 0.0001) and prior right bundle branch block (OR 10.22, 95% CI: 4.62-22.63; p < 0.0001). CONCLUSIONS: The recapturable capability of the Evolut R system allowed for higher and precise valve implantation. This fact had an impact on the reduction in the need for PPI.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Arritmias Cardíacas/terapia , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
3.
EuroIntervention ; 15(16): 1464-1470, 2020 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-30910769

RESUMO

AIMS: The aim of this study was to assess the efficacy and safety of percutaneous reintervention in patients who underwent aortic coarctation stenting at an early age. METHODS AND RESULTS: From 1993 to 2018, 177 patients with aortic coarctation were treated with stent implantation at our centre; 33 of them were treated at less than 12 years of age and required reintervention because of their rate of growth. The average age of the patients at the first and second procedure was 6±3 years and 19±7 years, respectively. At the reintervention procedure, 15 (45%) patients were treated with balloon re-expansion, and 18 (55%) were treated with re-stenting. Success was obtained in 30 patients (91%). The gradient across the coarctation changed from 22±10 mmHg to 6±6 mmHg, while the minimal lumen diameter increased from 9±6 mm to 15±3 mm. There were eight occlusions of the femoral artery (after the first procedure), and two covered stents were needed because of femoral bleeding. The mean follow-up time after the second procedure was 5±4 years. A third procedure was required only in three patients (9%). CONCLUSIONS: Patients with aortic coarctation treated with stent placement at an early age can be successfully re-treated after the completion of their somatic growth.


Assuntos
Angioplastia com Balão , Coartação Aórtica , Intervenção Coronária Percutânea/instrumentação , Stents , Criança , Pré-Escolar , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Recidiva , Resultado do Tratamento
4.
Rev. esp. cardiol. (Ed. impr.) ; 72(12): 1020-1030, dic. 2019. tab
Artigo em Espanhol | IBECS | ID: ibc-190766

RESUMO

Introducción y objetivos: Se describen los resultados en España de la segunda encuesta de la Sociedad Europea de Cardiología sobre terapia de resincronización cardiaca (CRT-Survey II) y se comparan con los de los demás países participantes. Métodos: Pacientes a los que se implantó un dispositivo de terapia de resincronización cardiaca entre octubre de 2015 y diciembre de 2016 en 36 centros participantes. Se recogieron datos sobre las características basales de los pacientes y del implante, y un seguimiento a corto plazo hasta el alta hospitalaria. Resultados: La tasa de éxito del implante fue del 95,9%. La mediana [intervalo intercuartílico] de implantes anuales/centro en España fue significativamente menor que en los demás países participantes: 30 [21-50] frente a 55 [33-100] implantes/año (p=0,00003). En los centros españoles hubo una menor proporción de pacientes de edad ≥ 75 años (el 27,9 frente al 32,4%; p=0,0071), una mayor proporción de pacientes en clase funcional II de la New York Heart Association (el 46,9 frente al 36,9%; p <0,00001) y un mayor porcentaje de pacientes con criterios electrocardiográficos de bloqueo de rama izquierda (el 82,9 frente al 74,6%; p <0,00001). La media de la estancia hospitalaria fue menor en los centros españoles (5,8+/-8,5 frente a 6,4+/-11,6; p <0,00001) y una mayor proporción de pacientes recibieron un cable de ventrículo izquierdo cuadripolar (el 74 frente al 56%; p <0,00001) y fueron seguidos a distancia (el 55,8 frente al 27,7%; p <0,00001). Conclusiones: La encuesta CRT-Survey II muestra que en España hay una menor proporción de pacientes de 75 o más años que reciben un dispositivo de terapia de resincronización cardiaca, una mayor proporción de pacientes en clase funcional II de la New York Heart Association, con bloqueo completo de la rama izquierda del haz de His y con seguimiento a distancia, con estancias hospitalarias significativamente menores


Introduction and objectives: We describe the results for Spain of the Second European Cardiac Resynchronization Therapy Survey (CRT-Survey II) and compare them with those of the other participating countries. Methods: We included patients undergoing CRT device implantation between October 2015 and December 2016 in 36 participating Spanish centers. We registered the patients' baseline characteristics, implant procedure data, and short-term follow-up information until hospital discharge. Results: Implant success was achieved in 95.9%. The median [interquartile range] annual implantation rate by center was significantly lower in Spain than in the other participating countries: 30 implants/y [21-50] vs 55 implants/y [33-100]; P=.00003. In Spanish centers, there was a lower proportion of patients ≥ 75 years (27.9% vs 32.4%; P=.0071), a higher proportion in NYHA class II (46.9% vs 36.9%, P <.00001), and a higher percentage with electrocardiographic criteria of left bundle branch block (82.9% vs 74.6%; P <.00001). The mean length of hospital stay was significantly lower in Spanish centers (5.8+/-8.5 days vs 6.4+/-11.6; P <.00001). Spanish patients were more likely to receive a quadripolar LV lead (74% vs 56%, P <.00001) and to be followed up by remote monitoring (55.8% vs 27.7%; P <.00001). Conclusions: The CRT-Survey II shows that, compared with other participating countries, fewer patients in Spain aged ≥ 75 years received a CRT device, while more patients were in New York Heart Association functional class II and had left bundle branch block. In addition, the length of hospital stay was shorter, and there was greater use of quadripolar LV leads and remote CRT monitoring


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Arritmias Cardíacas/terapia , Pesquisas sobre Atenção à Saúde/estatística & dados numéricos , Arritmias Cardíacas/epidemiologia , Insuficiência Cardíaca/epidemiologia , Eletrocardiografia/métodos , Espanha/epidemiologia , Europa (Continente)/epidemiologia , Estudos Retrospectivos
5.
Rev Esp Cardiol (Engl Ed) ; 72(12): 1020-1030, 2019 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-30935899

RESUMO

INTRODUCTION AND OBJECTIVES: We describe the results for Spain of the Second European Cardiac Resynchronization Therapy Survey (CRT-Survey II) and compare them with those of the other participating countries. METHODS: We included patients undergoing CRT device implantation between October 2015 and December 2016 in 36 participating Spanish centers. We registered the patients' baseline characteristics, implant procedure data, and short-term follow-up information until hospital discharge. RESULTS: Implant success was achieved in 95.9%. The median [interquartile range] annual implantation rate by center was significantly lower in Spain than in the other participating countries: 30 implants/y [21-50] vs 55 implants/y [33-100]; P=.00003. In Spanish centers, there was a lower proportion of patients ≥ 75 years (27.9% vs 32.4%; P=.0071), a higher proportion in New York Heart Association functional class II (46.9% vs 36.9%; P <.00001), and a higher percentage with electrocardiographic criteria of left bundle branch block (82.9% vs 74.6%; P <.00001). The mean length of hospital stay was significantly lower in Spanish centers (5.8±8.5 days vs 6.4±11.6; P <.00001). Spanish patients were more likely to receive a quadripolar LV lead (74% vs 56%; P <.00001) and to be followed up by remote monitoring (55.8% vs 27.7%; P <.00001). CONCLUSIONS: The CRT-Survey II shows that, compared with other participating countries, fewer patients in Spain aged ≥ 75 years received a CRT device, while more patients were in New York Heart Association functional class II and had left bundle branch block. In addition, the length of hospital stay was shorter, and there was greater use of quadripolar LV leads and remote CRT monitoring.


Assuntos
Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca/estatística & dados numéricos , Inquéritos e Questionários , Idoso , Arritmias Cardíacas/epidemiologia , Eletrocardiografia , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade/tendências , Estudos Retrospectivos , Espanha/epidemiologia
7.
Rev. esp. cardiol. (Ed. impr.) ; 71(6): 432-439, jun. 2018. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-178555

RESUMO

Introducción y objetivos: Hay escasa evidencia sobre el tratamiento de lesiones en bifurcación en relación con una oclusión coronaria crónica total (OCT). Este estudio analiza los resultados inmediatos y a medio plazo de pacientes con lesiones en bifurcación en OCT tratados con 1 stent provisional frente a 2 stents en un registro multicéntrico. Métodos: Entre enero de 2012 y junio de 2016, se recanalizaron 922 OCT en los 4 centros participantes. De ellas, 238 (25,8%) con lesión en bifurcación se trataron mediante estrategia simple (n = 201) o compleja (n = 37). Se calculó la puntuación de propensión emparejada para detectar sesgos entre ambos grupos. Los eventos adversos cardiovasculares mayores (MACE) se definieron como muerte cardiaca, infarto y revascularización de la lesión diana. Resultados: Los éxitos angiográfico y del procedimiento fueron similares con la técnica simple (el 94,5 frente al 97,3%; p = 0,48) y con la compleja (el 85,6 frente al 81,1%; p = 0,49), aunque la cantidad de contraste, la dosis de radiación y el tiempo de fluoroscopia fueron menores con la técnica simple. Al seguimiento (25 meses), la tasa de MACE fue del 8% de los pacientes con la técnica simple y el 10,8% de los tratados con 2 stents (p = 0,58). En este grupo hubo tendencia a una menor supervivencia libre de MACE (el 80,1 frente al 69,8%; p = 0,08). Después del análisis de propensión, no se observaron diferencias entre los grupos en los resultados inmediatos ni al seguimiento. Conclusiones: Las LB en OCT pueden tratarse de modo similar que las demás bifurcaciones, para las que el stent provisional es la técnica de elección. Después de la puntuación de propensión emparejada, no hubo diferencias en los resultados inmediatos y a medio plazo entre ambos grupos


Introduction and objectives: There is little evidence on the optimal strategy for bifurcation lesions in the context of a coronary chronic total occlusion (CTO). This study compared the procedural and mid-term outcomes of patients with bifurcation lesions in CTO treated with provisional stenting vs 2-stent techniques in a multicenter registry. Methods: Between January 2012 and June 2016, 922 CTO were recanalized at the 4 participating centers. Of these, 238 (25.8%) with a bifurcation lesion (side branch ≥ 2 mm located proximally, distally, or within the occluded segment) were treated by a simple approach (n = 201) or complex strategy (n = 37). Propensity score matching was performed to account for selection bias between the 2 groups. Major adverse cardiac events (MACE) consisted of a composite of cardiac death, myocardial infarction, and clinically-driven target lesion revascularization. Results: Angiographic and procedural success were similar in the simple and complex groups (94.5% vs 97.3%; P = .48 and 85.6% vs 81.1%; P = .49). However, contrast volume, radiation dose, and fluoroscopy time were lower with the simple approach. At follow-up (25 months), the MACE rate was 8% in the simple and 10.8% in the complex group (P = .58). There was a trend toward a lower MACE-free survival in the complex group (80.1% vs 69.8%; P = .08). After propensity analysis, there were no differences between the groups regarding immediate and follow-up results. Conclusions: Bifurcation lesions in CTO can be approached similarly to regular bifurcation lesions, for which provisional stenting is considered the technique of choice. After propensity score matching, there were no differences in procedural or mid-term clinical outcomes between the simple and complex strategies


Assuntos
Humanos , Oclusão Coronária/cirurgia , Stents , Intervenção Coronária Percutânea/métodos , Síndrome Coronariana Aguda/epidemiologia , Vasos Coronários/lesões , Inibidores da Agregação Plaquetária/uso terapêutico , Comorbidade , Resultado do Tratamento
8.
Eur J Hum Genet ; 26(7): 1014-1025, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29511324

RESUMO

Several studies have identified copy number variants (CNVs) as responsible for cardiac diseases associated with sudden cardiac death (SCD), but very few exhaustive analyses in large cohorts of patients have been performed, and they have been generally focused on a specific SCD-related disease. The aim of the present study was to screen for CNVs the most prevalent genes associated with SCD in a large cohort of patients who suffered sudden unexplained death or had an inherited cardiac disease (cardiomyopathy or channelopathy). A total of 1765 European patients were analyzed with a homemade algorithm for the assessment of CNVs using high-throughput sequencing data. Thirty-six CNVs were identified (2%), and most of them appeared to have a pathogenic role. The frequency of CNVs among cases of sudden unexplained death, patients with a cardiomyopathy or a channelopathy was 1.4% (8/587), 2.3% (20/874), and 2.6% (8/304), respectively. Detection rates were particularly high for arrhythmogenic cardiomyopathy (5.1%), long QT syndrome (4.7%), and dilated cardiomyopathy (4.4%). As such large genomic rearrangements underlie a non-neglectable portion of cases, we consider that their analysis should be performed as part of the routine genetic testing of sudden unexpected death cases and patients with SCD-related diseases.


Assuntos
Arritmias Cardíacas/genética , Cardiomiopatias/genética , Variações do Número de Cópias de DNA/genética , Morte Súbita Cardíaca/patologia , Adulto , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/patologia , Autopsia , Cardiomiopatias/epidemiologia , Cardiomiopatias/patologia , Morte Súbita Cardíaca/epidemiologia , Feminino , Testes Genéticos , Coração/fisiopatologia , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Masculino , Pessoa de Meia-Idade , Fenótipo
9.
Rev Esp Cardiol (Engl Ed) ; 71(6): 432-439, 2018 Jun.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29128364

RESUMO

INTRODUCTION AND OBJECTIVES: There is little evidence on the optimal strategy for bifurcation lesions in the context of a coronary chronic total occlusion (CTO). This study compared the procedural and mid-term outcomes of patients with bifurcation lesions in CTO treated with provisional stenting vs 2-stent techniques in a multicenter registry. METHODS: Between January 2012 and June 2016, 922 CTO were recanalized at the 4 participating centers. Of these, 238 (25.8%) with a bifurcation lesion (side branch ≥ 2mm located proximally, distally, or within the occluded segment) were treated by a simple approach (n=201) or complex strategy (n=37). Propensity score matching was performed to account for selection bias between the 2 groups. Major adverse cardiac events (MACE) consisted of a composite of cardiac death, myocardial infarction, and clinically-driven target lesion revascularization. RESULTS: Angiographic and procedural success were similar in the simple and complex groups (94.5% vs 97.3%; P=.48 and 85.6% vs 81.1%; P=.49). However, contrast volume, radiation dose, and fluoroscopy time were lower with the simple approach. At follow-up (25 months), the MACE rate was 8% in the simple and 10.8% in the complex group (P=.58). There was a trend toward a lower MACE-free survival in the complex group (80.1% vs 69.8%; P=.08). After propensity analysis, there were no differences between the groups regarding immediate and follow-up results. CONCLUSIONS: Bifurcation lesions in CTO can be approached similarly to regular bifurcation lesions, for which provisional stenting is considered the technique of choice. After propensity score matching, there were no differences in procedural or mid-term clinical outcomes between the simple and complex strategies.


Assuntos
Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea/instrumentação , Stents , Doença Crônica , Angiografia Coronária/mortalidade , Oclusão Coronária/mortalidade , Morte Súbita Cardíaca/etiologia , Métodos Epidemiológicos , Feminino , Fluoroscopia/mortalidade , Fluoroscopia/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Revascularização Miocárdica/instrumentação , Revascularização Miocárdica/métodos , Revascularização Miocárdica/mortalidade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/mortalidade , Doses de Radiação , Resultado do Tratamento
10.
Rev. esp. cardiol. (Ed. impr.) ; 70(7): 543-550, jul. 2017. graf, tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-164689

RESUMO

Introducción y objetivos: La reestenosis coronaria tras implantar un armazón vascular bioabsorbible (AVB) es infrecuente. Hay poca información disponible sobre las principales características de este tipo de lesiones. El objetivo de este estudio es caracterizar las reestenosis del AVB mediante tomografía de coherencia óptica (OCT). Métodos: Se estudió a 330 pacientes que recibieron 398 AVB para tratar 380 lesiones. Se evaluó a estos pacientes clínica y angiográficamente y, tras detectarse la reestenosis, mediante OCT. Resultados: Tras un seguimiento de 19 ± 10 meses, se detectaron 18 casos de reestenosis en 17 pacientes (5,4%). La mayoría eran tardías o muy tardías (9 ± 4 meses). El patrón angiográfico más frecuente fue la reestenosis focal en 12 (67%) y principalmente localizada en el borde proximal en 9 (75%), afectando o no la plataforma. El patrón predominantemente homogéneo fue infrecuente en 3 (25%) y solo se visualizó en 3 de las 6 reestenosis situadas en el margen. La reestenosis focal localizada dentro del armazón presentó en la OCT un patrón heterogéneo o en capas. Finalmente se observó reestenosis difusa en 6 casos (33%), en los que se identificó un patrón rico en lípidos o un patrón en capas. Además, se identificaron microvasos y microcalcificaciones en algunos de ellos, lo que sugiere un proceso de neoateroesclerosis. Conclusiones: La tasa de reestenosis tras una media de seguimiento de 19 meses fue del 5,4%. La presentación angiográfica más frecuente fue focal, situada en el borde proximal. La reestenosis difusa ocurrió tardía o muy tardíamente y la mayoría de estos pacientes presentaban signos de neoateroesclerosis (AU)


Introduction and objectives: Coronary restenosis after bioresorbable vascular scaffold (BVS) implantation is infrequent and little information is available on the main characteristics of these lesions. The aim of this study was to assess restenotic lesions by using optical coherence tomography (OCT). Methods: We studied 330 patients with coronary artery disease who received 398 BVS to treat 380 lesions. These patients were clinically and angiographically evaluated at follow-up and OCT was carried out on detection of restenosis. Results: After a follow-up of 19 ± 10 months, 18 restenotic lesions were detected in 17 patients (5.4%). Depending on the time of presentation, most cases of restenosis were late or very late (9 ± 4 months). The most frequent angiographic pattern was focal restenosis in 12 (67%) patients, which was mainly located at the proximal border in 9 (75%) whether involving the scaffold or not. The homogeneous pattern was infrequent, occurring in 3 (25%) lesions and was only visualized in 3 out of 6 cases of restenosis located at the margin. When the focal restenosis was located in the platform, OCT showed a heterogeneous or layered pattern. Finally, diffuse restenosis was observed in 6 patients (33%). In diffuse restenosis, OCT revealed a lipid-laden or layered tissue structure and the presence of microvessels or microcalcification, potentially suggesting a neoatherosclerotic process. Conclusions: After a mean follow-up of 19 months, the restenosis rate was 5.4%. Most restenotic lesions were focal, located at the proximal border. Diffuse restenosis mostly occurred late or very late and most showed signs suggestive of neoatherosclerosis (AU)


Assuntos
Humanos , Reestenose Coronária/diagnóstico , Stents Farmacológicos , Aterosclerose/cirurgia , Tomografia de Coerência Óptica , Angiografia Coronária , Implantes Absorvíveis , Everolimo/administração & dosagem
11.
Int J Cardiol ; 230: 432-438, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28041711

RESUMO

BACKGROUND: The presence of a bifurcation (BL) in the context of a coronary chronic total occlusion (CTO) represents an additional difficulty. This study analyzes the incidence of BLs in CTO recanalization, the treatment, predictors of bifurcation technical success and their clinical impact. METHODS AND RESULTS: BLs with a side branch (SB) ≥2.0mm located proximally, distally or within the occluded segment were observed in 130 (33%) of 391 CTO. Provisional stenting was the strategy more frequently used (94%). Bifurcation success (stenosis <30% in main vessel and TIMI flow III in both branches) was achieved in 105 patients (81%). In the remaining 25 (19%), the TIMI flow at the SB was

Assuntos
Oclusão Coronária/cirurgia , Intervenção Coronária Percutânea , Stents , Idoso , Doença Crônica , Estudos de Coortes , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/epidemiologia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
12.
Rev Esp Cardiol (Engl Ed) ; 70(7): 543-550, 2017 Jul.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-28132761

RESUMO

INTRODUCTION AND OBJECTIVES: Coronary restenosis after bioresorbable vascular scaffold (BVS) implantation is infrequent and little information is available on the main characteristics of these lesions. The aim of this study was to assess restenotic lesions by using optical coherence tomography (OCT). METHODS: We studied 330 patients with coronary artery disease who received 398 BVS to treat 380 lesions. These patients were clinically and angiographically evaluated at follow-up and OCT was carried out on detection of restenosis. RESULTS: After a follow-up of 19 ± 10 months, 18 restenotic lesions were detected in 17 patients (5.4%). Depending on the time of presentation, most cases of restenosis were late or very late (9 ± 4 months). The most frequent angiographic pattern was focal restenosis in 12 (67%) patients, which was mainly located at the proximal border in 9 (75%) whether involving the scaffold or not. The homogeneous pattern was infrequent, occurring in 3 (25%) lesions and was only visualized in 3 out of 6 cases of restenosis located at the margin. When the focal restenosis was located in the platform, OCT showed a heterogeneous or layered pattern. Finally, diffuse restenosis was observed in 6 patients (33%). In diffuse restenosis, OCT revealed a lipid-laden or layered tissue structure and the presence of microvessels or microcalcification, potentially suggesting a neoatherosclerotic process. CONCLUSIONS: After a mean follow-up of 19 months, the restenosis rate was 5.4%. Most restenotic lesions were focal, located at the proximal border. Diffuse restenosis mostly occurred late or very late and most showed signs suggestive of neoatherosclerosis.


Assuntos
Reestenose Coronária/diagnóstico , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos/efeitos adversos , Everolimo/farmacologia , Intervenção Coronária Percutânea/efeitos adversos , Tecidos Suporte/efeitos adversos , Tomografia de Coerência Óptica/métodos , Angiografia Coronária/métodos , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
13.
JACC Cardiovasc Interv ; 9(18): 1917-24, 2016 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-27659568

RESUMO

OBJECTIVES: The study sought to compare the safety (resistance to damage) and efficacy (ability to cross the side branch) of polymer-coated and non-polymer-coated guidewires in the jailed wire technique used during the percutaneous treatment of bifurcation lesions. BACKGROUND: The jailed wire technique is a useful strategy in the treatment of bifurcation lesions by provisional stenting. However, these wires can be damaged or even be broken during their removal. METHODS: We performed a randomized study in patients with bifurcation lesions treated by provisional stenting. The jailed wire technique was mandatory, and the types of guidewires, polymer-coated (n = 115) and non-polymer-coated (n = 120), were randomized. After the procedures, the wires were evaluated by stereoscopic microscopy. The induced damage in the wires was classified as follows: no damage, mild, moderate, or severe. RESULTS: The clinical characteristics were similar between patients treated with polymer-coated or non-polymer-coated wires. Polymer-coated wires were significantly (p < 0.001) more resistant to retrieval damage (only 2 wires showed mild damage) than were non-polymer-coated wires. However, 63 (55%) of the non-polymer-coated wires were damaged; 37 (32%), 24 (21%), and 2 (2%) had mild, moderate, and severe damage, respectively. Additionally, the jailed length of the wire was a factor contributing to the degree of wire damage. The time of side branch wiring was shorter in the polymer-coated wire group (19 ± 40 s vs. 42 ± 72 s; p < 0.05). CONCLUSIONS: Jailed wires during interventional procedures of bifurcation lesions commonly showed microscopic damage. Polymer-coated wires were more resistant to retrieval damage and were more efficient in crossing the side branch ostium than non-polymer-coated wires. (Jailed Wire Technique in the Treatment of Coronary Bifurcations Lesions With Stent: Stereoscopic Microscopy Study; NCT02516891).


Assuntos
Cateteres Cardíacos , Materiais Revestidos Biocompatíveis , Doença da Artéria Coronariana/terapia , Falha de Equipamento , Microscopia/métodos , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Método Simples-Cego , Espanha , Stents , Resultado do Tratamento
14.
Rev. esp. cardiol. (Ed. impr.) ; 69(6): 554-562, jun. 2016. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-152969

RESUMO

Introducción y objetivos: El tratamiento de lesiones coronarias con armazón vascular bioabsorbible ha demostrado ser eficaz. Hay poca información sobre su uso en bifurcaciones. El objetivo de este estudio es analizar la seguridad y la eficacia de esta plataforma en el tratamiento de bifurcaciones coronarias. Métodos: Desde enero de 2012 hasta enero de 2015, se trató con plataforma bioabsorbible a 194 pacientes con 230 lesiones en bifurcaciones coronarias. Se analizó con técnicas de imagen intracoronaria la geometría de 145 bifurcaciones (63%). El 78% de las lesiones se revaluaron angiográficamente (por tomografía computarizada, 138; por coronariografía, 41). Resultados: La presentación clínica más habitual fue un síndrome coronario agudo (81%). El tipo de bifurcación más frecuente (34%) fue la 1,1,1. La estrategia simple fue de elección en 221 lesiones (96%). En 90 lesiones se posdilató la rama lateral a través de las celdillas, y por tomografía de coherencia óptica se observó fractura del dispositivo en 3 casos. Se obtuvo éxito del procedimiento en todos los pacientes. En el primer mes se documentó 1 trombosis subaguda y 1 muerte súbita. El tiempo de seguimiento angiográfico fue de 7,3 ± 1,6 meses y el del seguimiento clínico, 14 ± 6 meses. Se observaron 12 restenosis (5%). Durante el seguimiento, 2 pacientes (1%) tuvieron un infarto en otro territorio y otros 2 fallecieron (1%); los demás quedaron libres de síntomas. La tasa de trombosis fue del 1,3%. Conclusiones: El tratamiento de lesiones en bifurcaciones coronarias con armazón vascular bioabsorbible provisional es seguro y eficaz. Al seguimiento, había una tasa de eventos adversos baja (AU)


Introduction and objectives: The treatment of coronary lesions with a bioresorbable vascular scaffold has been shown to be effective. However there is little information about its use in bifurcations. The aim of this study was to analyze the safety and efficacy of the bioresorbable scaffold in the treatment of coronary bifurcation lesions. Methods: From January 2012 to January 2015, we used a bioresorbable vascular scaffold to treat 194 patients with 230 bifurcation lesions. The scaffold geometry was examined by intracoronary imaging techniques in 145 bifurcations (65%). In all, 78% of the bifurcations were evaluated angiographically during follow-up (computed tomography angiography in 138 and coronary angiography in 41). Results: The most common clinical presentation was acute coronary syndrome (81%). The most frequent type of bifurcation was 1,1,1 (34%). A simple approach was the chosen strategy in 221 bifurcations (96%). In 90 of these lesions, the side branch was postdilated through the cells of the platform and, in 3 cases, strut fractures were observed in optical coherence tomography. Procedural success was achieved in all patients. There was 1 case of subacute thrombosis and 1 sudden cardiac death during the first month. The duration of angiographic follow-up was 7.3 ± 1.6 months and that of clinical follow-up, 14 ± 6 months. Twelve (5%) restenoses were documented and revascularized. During follow-up, 2 patients (1%) had an infarction in another territory and another 2 patients (1%) died; the remaining patients had a symptom-free follow-up. The incidence of thrombosis was 1.3%. Conclusions: Treatment of bifurcation coronary lesions using a provisional approach is feasible and safe, with a low rate of adverse events (AU)


Assuntos
Humanos , Doença das Coronárias/cirurgia , Intervenção Coronária Percutânea/métodos , Stents Farmacológicos , Reestenose Coronária/prevenção & controle , Vasos Coronários/lesões , Tecidos Suporte , Implantes Absorvíveis , Angiografia Coronária
15.
Rev Esp Cardiol (Engl Ed) ; 69(6): 554-62, 2016 Jun.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-26949014

RESUMO

INTRODUCTION AND OBJECTIVES: The treatment of coronary lesions with a bioresorbable vascular scaffold has been shown to be effective. However there is little information about its use in bifurcations. The aim of this study was to analyze the safety and efficacy of the bioresorbable scaffold in the treatment of coronary bifurcation lesions. METHODS: From January 2012 to January 2015, we used a bioresorbable vascular scaffold to treat 194 patients with 230 bifurcation lesions. The scaffold geometry was examined by intracoronary imaging techniques in 145 bifurcations (65%). In all, 78% of the bifurcations were evaluated angiographically during follow-up (computed tomography angiography in 138 and coronary angiography in 41). RESULTS: The most common clinical presentation was acute coronary syndrome (81%). The most frequent type of bifurcation was 1,1,1 (34%). A simple approach was the chosen strategy in 221 bifurcations (96%). In 90 of these lesions, the side branch was postdilated through the cells of the platform and, in 3 cases, strut fractures were observed in optical coherence tomography. Procedural success was achieved in all patients. There was 1 case of subacute thrombosis and 1 sudden cardiac death during the first month. The duration of angiographic follow-up was 7.3±1.6 months and that of clinical follow-up, 14±6 months. Twelve (5%) restenoses were documented and revascularized. During follow-up, 2 patients (1%) had an infarction in another territory and another 2 patients (1%) died; the remaining patients had a symptom-free follow-up. The incidence of thrombosis was 1.3%. CONCLUSIONS: Treatment of bifurcation coronary lesions using a provisional approach is feasible and safe, with a low rate of adverse events.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Reestenose Coronária/epidemiologia , Estenose Coronária/terapia , Tecidos Suporte , Síndrome Coronariana Aguda/etiologia , Idoso , Angioplastia Coronária com Balão , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Técnicas In Vitro , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/instrumentação , Sistema de Registros , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção
16.
EuroIntervention ; 11(11): e1283-90, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26865446

RESUMO

AIMS: The behaviour of side branches (SBs) covered by a bioresorbable vascular scaffold (BVS) is not well known. This study analysed the rate of side branch occlusion (SBO) immediately after BVS implantation, its clinical impact, predictors of SBO and the fate of such SBs at follow-up. METHODS AND RESULTS: We assessed 140 patients with 346 jeopardised SBs divided into three groups: small (<1 mm, n=181), intermediate (1-2 mm, n=102) and large (>2 mm, n=63). SBO was defined as a TIMI flow 0 or 1. Computed tomography was scheduled at six months for patients with jailed SBs >1 mm. Immediate occlusion occurred in 31 (9%) SBs: 22 (12%) small, 8 (8%) intermediate and one (1.6%) large, while post-procedural SBO was 5.5%. In-hospital events included one thrombosis (0.7%) and eight non-Q-wave myocardial infarctions (6%). After 17±3 months, one patient died (0.7%) and six patients needed repeat revascularisation (4%). Re-evaluation showed no late SBO at 7±3 months. Predictors of SBO were: small SBs (OR 2.06, 95% CI: 1.08-4.63; p<0.05) and stenosis >50% at the origin (OR 17.22, 95% CI: 7.79-38.10; p<0.01). CONCLUSIONS: The incidence of SBO and its clinical impact were low when SBs >1 mm were covered. These favourable results were maintained at midterm.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/uso terapêutico , Doença da Artéria Coronariana/diagnóstico por imagem , Stents Farmacológicos , Everolimo/uso terapêutico , Infarto do Miocárdio/diagnóstico por imagem , Idoso , Angioplastia Coronária com Balão/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Tomografia Computadorizada por Raios X , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 87(5): E173-82, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26268440

RESUMO

OBJECTIVES: To analyze the feasibility and safety of direct bioresorbable vascular scaffold (BVS) implantation without previous balloon dilation. BACKGROUND: Lesion preparation through predilation is recommended before BVS implantation. There is no information on the routine use of direct BVS implantation. METHODS AND RESULTS: One hundred fifty-three patients with a total of 200 coronary lesions, were treated with BVS. A baseline intravascular ultrasound study (IVUS) was performed in 171 lesions (86%), and after BVS implantation, the quality of scaffolding was assessed with an additional IVUS (83, 41%) or optical coherence tomography (77, 38%). Elective predilation was conducted in 50 lesions. In 150 lesions, direct BVS implantation was attempted. In 129 lesions (86%), the BVS was implanted successfully, and in the remaining 21 (14%), direct implantation failed. In these cases, the scaffolds were retrieved and successfully implanted after balloon angioplasty. Longer and C-type lesions, and a larger plaque burden, were associated with failure to directly cross the lesion. Balloon postdilation was needed in 34% of the lesions. Ten patients (6.6%) had a periprocedural myocardial infarction. One patient (0.6%) died 60 days after BVS implantation due to thrombosis of the scaffold. At follow-up, target lesion revascularisation was needed in eight patients (5%). After 12 ± 3 months, the remaining patients were symptom-free. CONCLUSIONS: Direct BVS implantation is safe and feasible in most soft coronary plaques.


Assuntos
Implantes Absorvíveis , Cateteres Cardíacos , Doença da Artéria Coronariana/terapia , Vasos Coronários , Intervenção Coronária Percutânea/instrumentação , Idoso , Angioplastia Coronária com Balão , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Intervalo Livre de Doença , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Espanha , Fatores de Tempo , Tomografia de Coerência Óptica , Resultado do Tratamento , Ultrassonografia de Intervenção
18.
Rev. esp. cardiol. (Ed. impr.) ; 68(12): 1111-1117, dic. 2015. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-145617

RESUMO

Introducción y objetivos: La técnica de la guía encarcelada resulta de gran utilidad en el tratamiento de lesiones bifurcadas mediante la técnica de stent condicional. Sin embargo, esta guía puede sufrir daño e incluso fracturarse en el momento de la retirada. El objetivo de este estudio es evaluar la aparición de daño estructural en las guías encarceladas, tanto poliméricas como no poliméricas. Métodos: Entre enero de 2011 y diciembre de 2012 se realizó un estudio observacional en el que se evaluaron mediante microscopia estereoscópica 135 guías (45 no poliméricas y 90 poliméricas) utilizadas previamente en el tratamiento percutáneo de bifurcaciones y que resultaron encarceladas. El daño tras la extracción se valoró como leve, moderado o grave. Resultados: Las distribuciones de edad y sexo fueron similares en los dos grupos de pacientes tratados con guías poliméricas y no poliméricas. Sin embargo, los operadores seleccionaron las guías poliméricas con más frecuencia en bifurcaciones más complejas y en pacientes diabéticos. Se observó algún tipo de daño microscópico en 25 de las guías analizadas (18%). Paradójicamente, estas alteraciones fueron más frecuentes en el grupo de guías no poliméricas (el 53,0 frente al 1,1%; p < 0,001). Solo se produjo daño grave en 2 casos (1,5%). No se produjo ninguna rotura completa de la guía. Conclusiones: Las guías coronarias que se encarcelan durante el tratamiento de las bifurcaciones con stentcondicional presentan a menudo daño microscópico no grave. Aunque las guías poliméricas se utilizaron en bifurcaciones más complejas, paradójicamente se dañaron con menos frecuencia (AU)


Introduction and objectives: The use of the jailed guidewire technique is highly useful when treating bifurcation lesions by provisional stenting. However, at the time of withdrawal, the guidewire can suffer damage and even fracture. The aim of this study was to evaluate structural damage in both polymercoated and nonpolymer-coated jailed guidewires. Methods: Between January 2011 and December 2012, an observational study was conducted using stereoscopic microscopy to evaluate 135 jailed guidewires (45 nonpolymer-coated and 90 polymercoated) previously used in the percutaneous treatment of bifurcation lesions. Damage after withdrawal was classified as mild, moderate, or severe. Results: Age and sex distributions were similar in both groups of patients treated with polymer-coated and nonpolymer-coated guidewires. However, operators selected polymer-coated guidewires more frequently when treating more complex bifurcations and in diabetic patients. Some type of microscopic damage was observed in 25 of the guidewires analyzed (18%). Paradoxically, damage was more common in nonpolymer-coated guidewires (53.0% vs 1.1%; P < .001). None of the guidewires suffered complete fracture. Conclusions: Coronary guidewires that are jailed during the treatment of bifurcations using provisional stenting often suffer nonsevere microscopic damage. Although polymer-coated guidewires were used in more complex bifurcation lesions, paradoxically, they were damaged less frequently (AU)


Assuntos
Humanos , Angioplastia Coronária com Balão/métodos , Doença das Coronárias/cirurgia , Ponte de Artéria Coronária , Regeneração Tecidual Guiada
19.
Am J Cardiol ; 116(7): 1045-9, 2015 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-26243578

RESUMO

The possibility of strut fractures after bioresorbable vascular scaffold (BVS) treatment is a new problem associated with the use of this novel technology. There is little in vivo information regarding the effects of lateral dilation on BVS. The present study aimed to evaluate the effects of lateral balloon dilation after bioresorbable vascular scaffold implantation in the treatment of bifurcation lesions. From January 2012 to February 2015, 49 patients with bifurcation lesions who had been treated with BVS required balloon dilation of the side branch (SB). Optical coherence tomographic studies were performed in each of these patients. In 3 patients (6%), the optical coherence tomographic results met the criteria for rupture. Prolonged inflation using a noncompliant balloon with a diameter within the expansion limits of the device resolved the complication in all patients. The clinical course was favorable in all patients, and there were no inhospital deaths or myocardial infarctions. At 14 ± 8 months of follow-up, 2 patients with integrity of the BVS presented target lesion revascularization (4%). Another patient (2%) suffered a probable stent thrombosis 11 months after the procedure (myocardial infarction and death at home). The patients with the BVS rupture at the index procedure had a favorable clinical outcome, and the 6-month computed tomographic scan revealed maintenance of the initial good results. In conclusion, minor BVS rupture after 2.5-mm lateral balloon dilation may occur but is infrequent (6%). Prolonged balloon inflation of the main vessel may partially restore the geometry of the BVS.


Assuntos
Implantes Absorvíveis/efeitos adversos , Angioplastia Coronária com Balão/efeitos adversos , Estenose Coronária/cirurgia , Stents/efeitos adversos , Tecidos Suporte , Angioplastia Coronária com Balão/métodos , Estenose Coronária/diagnóstico , Vasos Coronários/patologia , Vasos Coronários/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Tomografia de Coerência Óptica
20.
JACC Cardiovasc Interv ; 8(10): 1368-1379, 2015 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-26315741

RESUMO

OBJECTIVES: This study sought to determine whether several anatomic or evolving characteristics of the coarctation may create challenging conditions for treatment. BACKGROUND: Stent repair of coarctation of aorta is an alternative to surgical correction. METHODS: We analyzed our 21-year experience in the percutaneous treatment of complex coarctation of aorta. Adverse conditions for treatment were as follow: 1) complete interruption of the aortic arch (n = 11); 2) associated aneurysm (n = 18); 3) complex stenosis (n = 30); and 4) the need for re-expansion and/or restenting (n = 21). Twenty patients (33%) belonged to more than 1 group. Ten interruptions were type A and 1 was type B. The mean length of the interrupted aorta was 9 ± 11 mm. The associated aneurysms were native in 8 patients and after previous intervention in 10 patients. Aneurysm shapes were fusiform in 8 patients and saccular in 10. The following characteristics defined complex stenosis as long diffuse stenosis, very tortuous coarctation, or stenosis involving a main branch or an unusual location. Patients previously stented at an early age, required re-expansion and/or restenting after reaching 16 ± 5 years of age. RESULTS: Two patients had died by 1-month follow-up. The remaining 58 patients did well and were followed-up for a mean period of 10 ± 6 years. Late adverse events occurred in 3 patients (5%). All remaining patients are symptom-free, with normal baseline blood pressure. Imaging techniques revealed good patency at follow-up without associated aneurysm or restenosis. The actuarial survival free probability of all complex patients at 15 years was 92%. CONCLUSIONS: Stent repair of complex coarctation of aorta is feasible and safe. Initial results are maintained at later follow-up.


Assuntos
Aneurisma Aórtico/terapia , Coartação Aórtica/terapia , Arteriopatias Oclusivas/terapia , Procedimentos Endovasculares/instrumentação , Stents , Adolescente , Adulto , Idoso , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/mortalidade , Aneurisma Aórtico/fisiopatologia , Coartação Aórtica/diagnóstico , Coartação Aórtica/mortalidade , Coartação Aórtica/fisiopatologia , Aortografia/métodos , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/mortalidade , Arteriopatias Oclusivas/fisiopatologia , Criança , Pré-Escolar , Constrição Patológica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Espanha , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Grau de Desobstrução Vascular , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...